Ozone System Maintenance
Keep your water crystal clear and bacteria-free with proper ozone management.
1. Check for Bubbles

The "Champagne" Stream
Ozone gas is injected into the water via a Venturi system. You should see a steady stream of fine bubbles entering the tub from the return jet whenever the pump is running.
No Bubbles?
This usually means low water flow. Clean your filter immediately. If flow is weak, the ozone injector cannot create the suction needed to pull gas into the water.
2. How to Measure ORP
Using an ORP Meter- ORP (Oxidation Reduction Potential) measures the water's ability to sanitize itself. It is the most accurate way to test your water quality.
1. Prepare
Remove the protective cap from the ORP meter. If the meter has been dry for a long time, soak the tip in tap water for 5 minutes.
2. Measure
Turn the meter ON. Submerge the probe tip into the ice bath water (about 1-2 inches). Swirl it gently to remove air bubbles from the sensor.
3. Read & Rinse
Wait for the number to stabilize (this can take 30-60 seconds). Record the reading. Rinse the probe with fresh tap water before putting the cap back on.
Target Levels

Quick Tips
-
Reading > 800mV? Run ozone less.
-
Reading < 650mV? Clean filter & run pump 24/7.
Need a Meter?
A handheld digital ORP meter that reads in millivolts (mV) is all you need. Here's the one we use.
Check Ozone in the Air
If your ice bath is indoors, we recommend checking the ozone level in the air. Turn the detector on and wait until it reads 0.0 ppm, then hold it at head level over the ice bath for 30 seconds. Most of the time it will read 0.0 ppm even when you can smell ozone. Your nose is about 10 times more sensitive than the detector, so smelling ozone is not a reason for concern. If the ozone smell is strong when you open the lid, wait 30-60 seconds before getting in.